Frequency controller for electromagnetic feeder up to 6 A with a solid-state appearance.

General Details

Microprocessor digital professional controller with visualized frequency and amplitude – Delay 8 sec max On/Off vibrator with sensor NPN/PNP or relay contact – Automatic Input from PLC 0/10V – 4/20mA – Status relay.

General Characteristics

  • Voltage from 100V to 250V, 50/60 Hz
  • 3000/6000 Vib/min
  • Double Input ON/OFF
  • Soft/fast ramp
  • Manual Regulation amplitude/frequency ( 30/80Hz – 80/130Hz) min/max
  • Limitation Max Output current
  • Line input with schuko plug
  • Vibrator output  with connector.

Options

  • Personalized label
  • Connector for vibrator
  • Frequency Meter.

Applications

Digital regulation of linear and bowl feeder till 6,3 Amps – The FQ1 dig allows optimizing operation of the vibratory feeder by searching for its resonance frequency (max performance) thereby eliminating its lengthy and difficult mechanical calibration.

Available Versions

ModelVersionColourDimensionsCode
FQ1PWM/BIP65 – Basic (1pot. – No display)RAL 7035195 x 130 x 90PV FQ1PW Z2 SMB
FQ1PWM/B35“Basic” IP20 DIN35 (1pot. – NO display)195 x 120 x 50PV FQ1PW D2 STB
FQ1PWMMetallic Box IP65 (2pot.+display)RAL 7035195 x 130 x 90PV FQ1PW Z2 SM1
FQ1PWM/35Circuit IP20 DIN35 (2pot.+display)195 x 120 x 50PV FQ1PW D2 STD
FQ1PWMKIP65 – Keys versionRAL 7035195 x 130 x 90PV FQ1PW Z2 SMK
FQ1PWM/BDIP65 Basic Display (1pot. + display)RAL
7035
195 x 130 x 90PV FQ1BD Z2 STD
FQ1PWM/BD35IP20 Basic Display – DIN35195 x 120 x 50PV FQ1BD D2 STD
Characteristics
Tension of Feeding 115V or 230V ± 5% 50/60Hz
Consumption 2,5W max
Current Max 6,3A (RMS)
Load Min 50 mA (RMS)
Frequency of Vibration 30/80Hz(50Hz) – 80/130Hz(100Hz)
Time of Ramp 1 sec.
Input Sensor NPN/PNP or Free voltage contact
Automatic Input 0/10V-0/20mA (with 470 Ohm)
On/Off free contact
Delay ON/OFF 0/8 sec
Degree of Protection IP65 in box (NEMA4-4X)
Temperature Of Storage -15°C./ + 80°C
Temperature of Operation –5°C / +55°C
Altitude till to 2000 meters
European Norms EMC CE
Guarantee 1 year (from date on circuit)

 